• CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
  • CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
  • CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
  • CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
  • CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
  • CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System

CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System

Applicable Departments: Oral Surgery
Certification: ISO, CE
Type: X-Ray Equipment
Material: Aluminum
Warranty: 2 Years
Design: Floor-Type
Samples:
US$ 780/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ADS-M1
Voltage
AC220V±10%,50Hz,1kVA
Tube Voltage
60kv
Total Filtration
2.5mmal
Focus Size
0.8mm or 0.4mm (as Per Denmand of End-User)
Tube Current
8mA
Radiation Focus
0.8mm
Time of Exposure
0.02-4s
Tube-Head Voltage
70kv±10%
Radiation Leakage
Outside 1m<0.002mgy/H
Transport Package
Carton
Trademark
ADELSON
Origin
China
HS Code
9018499000
Production Capacity
2000 Units/Month

Product Description

CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
Feature:
1.Using the international advanced technology,efficient integrated design,high efficiency,low radiation.
2.Using microcomputer intelligent control,not only remote controlled exposure,but more powerful function of low voltage alarm and high voltage protection.
3.Micro focus technology,much more clear image and accurate diagnosis.
4.The base has two modes of mobile and fixed ,pneumatic lift soat ensures more convenient for dentist and more comfortable for patient.
5.Can use lightroom dental film,imaging in one minute,maximum convenient dentist to diagnose.
6.Can connect to dental digital imaging system,that is indispensable for clinicians to diagnose and root canal filling.

Power supply AC220V+10%,50Hz,1KVA
Tube voltage 60kV
Tube current 8mA
Focus size 0.8mm or 0.4mm (as per denmand of end-user)
Total filtration 2.5mmAL
Exposure time 0.2-4sec
Leak radiation outside one meter<=0.002mGy/h,(national standard:0.25mGy/h)
Package size:

180x38x26CM

Main body size:

145x50x26cm

Base size:

81x69x7cm

Net weight 47KGS
Gross weight: 57KGS

Precautions:

1. In order to ensure safety in operation and use, good ground lead must be installed well.
2. Because small X-ray machine's thermal capacity is limited, attention should be paid to making the machine work intermittently.
3. Only during exposure process this machine will produce X-rays. It won't produce X-rays in power-off state, neither in power-on state as long as not in exposure.
4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified.
5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets.
6. Every time when disassembling the machine, disassemble the head first and then other parts.
8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position.
9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol.
10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well.
11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like.
13. The rated capacity of the machine is 1.1 kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5 KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage. 
 

CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System


CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System

 

 
CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging SystemCE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
CE Good Price Dental Mobile X-ray Intra Machine Oral Imaging System
FAQ: 
1. Q: Where is your factory located? How can I visit there? 
A: Our factory is located in Foshan City,Guangdong Province,China,near Guangzhou.You can fly to Baiyun airport,you can take tax or metro to Foshan directly.All our clients,from home or abroad,are warmly welcome to visit us! 

2. Q: How long is my warranty and what does it cover? 
A: Carry the full one year manufacturer warranty. Each warranty period begins at the date of delivery date and ends after one year. The warranty varies by option items and manufacturer All warranty claims will be void due to neglect, lack of maintenance, and/or improper handling. 

3. How can I get the after sevice? How can I get the spare part after one year warranty? 
A: We welcome your chats online (Chat or leave message: After service) or e-mail to us regarding any technical or related questions that you may have. 


If you want to know more information about our products welcome to contact us in any time, And welcome to our company

Contact
Contact person: Allen Song

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.